Development v12

Warning - Product Update

All the resources present on this section belong to Waspmote v12, Waspmote Plug & Sense! v12 and Meshlium v3.8.

If you have a Waspmote v15, Waspmote Plug & Sense! v15 or Meshlium v4.0 please go to the new Development Section.

Check what is your version and what are the differences between the old and the new one in this document.

Examples:

Sensors / Gases PRO Board

» GP 01: CO

Last edition: Jan 10th, 2017 | Categories: Sensors, Gases PRO Board

This is the basic code to manage and read the carbon monoxide (CO) gas sensor. The concentration and the enviromental variables will be stored in a frame. Cycle time: 5 minutes

» GP 02: CO2

Last edition: Jan 10th, 2017 | Categories: Sensors, Gases PRO Board

This is the basic code to manage and read the carbon dioxide (CO2) gas sensor. The concentration and the enviromental variables will be stored in a frame. Cycle time: 5 minutes

» GP 03: O2

Last edition: Jan 10th, 2017 | Categories: Sensors, Gases PRO Board

This is the basic code to manage and read the molecular oxygen (O2) gas sensor.. The concentration and the enviromental variables will be stored in a frame. Cycle time: 5 minutes

» GP 04: O3

Last edition: Jan 10th, 2017 | Categories: Sensors, Gases PRO Board

This is the basic code to manage and read the ozone (O3) gas sensor. The concentration and the enviromental variables will be stored in a frame. Cycle time: 5 minutes

» GP 05: NO

Last edition: Jan 10th, 2017 | Categories: Sensors, Gases PRO Board

This is the basic code to manage and read the nitric oxide (NO) gas sensor. The concentration and the enviromental variables will be stored in a frame. Cycle time: 5 minutes

» GP 06: NO2

Last edition: Jan 10th, 2017 | Categories: Sensors, Gases PRO Board

This is the basic code to manage and read the nitric dioxide (NO2) gas sensor. The concentration and the enviromental variables will be stored in a frame. Cycle time: 5 minutes

» GP 07: SO2

Last edition: Jan 10th, 2017 | Categories: Sensors, Gases PRO Board

This is the basic code to manage and read the sulfur dioxide (SO2) gas sensor. The concentration and the enviromental variables will be stored in a frame. Cycle time: 5 minutes

» GP 08: NH3

Last edition: Jan 10th, 2017 | Categories: Sensors, Gases PRO Board

This is the basic code to manage and read the ammonia (NH3) gas sensor. The concentration and the enviromental variables will be stored in a frame. Cycle time: 5 minutes

» GP 09: CH4

Last edition: Jan 10th, 2017 | Categories: Sensors, Gases PRO Board

This is the basic code to manage and read the methane (CH4) and other combustible gases sensor. The concentration and the enviromental variables will be stored in a frame. Cycle time: 5 minutes

» GP 10: H2

Last edition: Jan 10th, 2017 | Categories: Sensors, Gases PRO Board

This is the basic code to manage and read the molecular hydrogen (H2) gas sensor. The concentration and the enviromental variables will be stored in a frame. Cycle time: 5 minutes

» GP 11: H2S

Last edition: Jan 10th, 2017 | Categories: Sensors, Gases PRO Board

This is the basic code to manage and read the hydrogen sulfide (H2S) gas sensor. The concentration and the enviromental variables will be stored in a frame. Cycle time: 5 minutes

» GP 12: HCl

Last edition: Jan 10th, 2017 | Categories: Sensors, Gases PRO Board

This is the basic code to manage and read the hydrogen chloride (HCl) gas sensor. The concentration and the enviromental variables will be stored in a frame. Cycle time: 5 minutes

» GP 13: HCN

Last edition: Jan 10th, 2017 | Categories: Sensors, Gases PRO Board

This is the basic code to manage and read the hydrogen cyanide (HCN) gas sensor. The concentration and the enviromental variables will be stored in a frame. Cycle time: 5 minutes

» GP 14: PH3

Last edition: Jan 10th, 2017 | Categories: Sensors, Gases PRO Board

This is the basic code to manage and read the carbon phosphine (PH3) gas sensor. The concentration and the enviromental variables will be stored in a frame. Cycle time: 5 minutes

» GP 15: ETO

Last edition: Jan 10th, 2017 | Categories: Sensors, Gases PRO Board

This is the basic code to manage and read the ethylene oxide (ETO) gas sensor. The concentration and the enviromental variables will be stored in a frame. Cycle time: 5 minutes

» GP 16: Cl2

Last edition: Jan 10th, 2017 | Categories: Sensors, Gases PRO Board

This is the basic code to manage and read the chlorine (Cl2) gas sensor. The concentration and the enviromental variables will be stored in a frame. Cycle time: 5 minutes

» GP 17: AQM

Last edition: Jan 10th, 2017 | Categories: Sensors, Gases PRO Board

This is the basic code to manage and read CO, O3, SO2 and NO2 gas sensors. This gases are commonly meassured in air quality monitors. The concentration and the enviromental variables will be stored in a frame. Cycle time: 5 minutes.

» GP 19: AQM with particle

Last edition: Jan 10th, 2017 | Categories: Sensors, Gases PRO Board

This is the basic code to manage and read CO, O3, SO2, NO2 gas sensors and a prticle sensor. This gases are commonly meassured in air quality monitors. The concentration and the enviromental variables will be stored in a frame.